机架式系列UPS采用双转化在线,包括1KVA至6KVA。为负载提供的电源环境,能彻底解决市电带来的问题,机架式的结构是网络应用中的结构方式,能通信系统和网络机房的布局效率,对电力环境要求苛刻的设备提供更加灵活、的电源保护。
BS-R SERI | ||||
Model | BS-R 1K | BS-R 2K | BS-R 3K | BS-R 6K |
Rated power | ||||
VA/W | 1kVA/0.7kW | 2kVA/1.4kW | 3kVA/2.1kW | 6kVA/4.2kW |
Input | ||||
mina Voltage | 110VAX/220VAC | 220VAC | ||
Voltage Range | 115-300VAC/60-138VAC | 176-276VAC | ||
Frequency Range | 46-54Hz(default),user adjustable within 40-60Hz | 46-54Hz | ||
Power Factor | 0.97 | 0.98 | ||
Connection | IEC320-10A inlet | IEc320-16Ainlet | Terminal Block | |
Output | ||||
Voltage | 220VAC/110vac&plun;2% | 220VAC&plun;1% | ||
Frequency | 50Hz&plun;0.2Hz(Battery mode) | 50Hz&plun;0.05Hz (battery mode) | ||
Waveform | Sine Wave | |||
Powerfactor | 0.7 | |||
Voltage Distortion | 2%under linear load | |||
Overload Capability | 108%-150% for 30 sec.,150%for 300ms | 105%-130% for 10 min.,130% for 1min. | ||
Current Crt Ratio | 3:1 | |||
B | ||||
Automatic Transfer | on overload and UPS failure | |||
Befoue UPS Power-on | Default"",user adjustable to"Y" | Y | ||
Transtfe Time Zero | ||||
LED/LCD Indicators | ||||
Status | Load Level/Battery level,Battery,Utility power,Inverter,B,Overload,Fault | |||
Audible Alarm B,On battery mode,Battery low,Overload,Fault | ||||
Communications | ||||
RS232 serial interface | ||||
Intelligent Slot | Options:webpower snmp/web card,as400 card or winpower cmc | |||
Ennvironmental | ||||
Operating Temperature | 0-40℃ | |||
Operating Humidity | 20-90%n-condemsing | |||
Weight | ||||
Net(Kg) | 15.3 | 10.3 | 11.2 | 18.3 |
Dimensions | ||||
W&tim;D&tim;H(mm) | 428.6&tim;450&tim;88(2U) | 482.6&tim;600&tim;130(3U) | ||
Battery Pack | ||||
Te | Internal Batteri | External Battery Pack | ||
minal DC Voltage | 36VDC | 96VDC | 240VDC
|