T83-A230X B88069X8910B502为EPCOS陶瓷气体放电管,直流导通电压230V,雷击电流10KA,三端引脚插件系列,使用在室外感应雷区,大量使用在电源产品防雷;海普森做放电管自家常备库存,长期现货供应国内外品牌放电管,欢迎来电咨询。
下面是常见参数:
Electrical specifications
DC spark-over voltage 230 V 正负20%
Impulse spark-over voltage
at 100 V/us - for 99 % of measured values < 500V
- typical values of distribution < 450V
at 1 kV/us - for 99 % of measured values < 600V
- typical values of distribution < 550V
Service life
10 operations 50 Hz, 1 s10A
10 operations [5x (+) & 5x (-)] 8/20 us 10 kA
1 operation 8/20 us 15 kA
300 operations 10/1000 us200 A
Insulation resistance at 50 V > 10 GO
Capacitance at 1 MHz < 1.5 pF
Arc voltage at1 A ~ 15V
Glow to arc transition current ~0.6A
Glow voltage ~ 60V
Weight ~1.5 g
Operation and storage temperature -40 ... +125 °C
Climatic category (IEC 60068-1) 40/ 125/ 21
Marking, blue negative EPCOS 230 YY O
90 - Nominal voltage
YY - Year of production
O - Non radioactive
T83-A230X B88069X8910B502为EPCOS陶瓷气体放电管,直流导通电压230V,雷击电流10KA,三端引脚插件系列,两端直脚,中间垂直,使用在室外感应雷区,大量使用在电源产品防雷;海普森做放电管自家常备库存,长期现货供应国内外品牌放电管,欢迎来电咨询。 下面是常见参数: Electrical specifications DC spark-over voltage 230 V 正负20% Impulse spark-over voltage at 100 V/us - for 99 % of measured values < 500V - typical values of distribution < 450V at 1 kV/us - for 99 % of measured values < 600V - typical values of distribution < 550V Service life 10 operations 50 Hz, 1 s10A 10 operations [5x (+) & 5x (-)] 8/20 us 10 kA 1 operation 8/20 us 15 kA 300 operations 10/1000 us200 A Insulation resistance at 50 V > 10 GO Capacitance at 1 MHz < 1.5 pF Arc voltage at1 A ~ 15V Glow to arc transition curr...
T80-A230X B88069X9380C203 为EPCOS陶瓷气体放电管,直流导通电压230V,雷击电流10KA,三端贴片系列,三端都是圆形;使用在室外感应雷区,大量使用在电源产品防雷;海普森做放电管自家常备库存,长期现货供应国内外品牌放电管,欢迎来电咨询。 下面是常见参数: Electrical specifications DC spark-over voltage 230 V 正负20% Impulse spark-over voltage at 100 V/us - for 99 % of measured values < 500V - typical values of distribution < 450V at 1 kV/us - for 99 % of measured values < 600V - typical values of distribution < 550V Service life 10 operations 50 Hz, 1 s10A 10 operations [5x (+) & 5x (-)] 8/20 us 10 kA 1 operation 8/20 us 15 kA 300 operations 10/1000 us200 A Insulation resistance at 50 V > 10 GO Capacitance at 1 MHz < 1.5 pF Arc voltage at1 A ~ 15V Glow to arc transition current ~0.6...