Contact rating per pole and load type |
Load Current in Amps @115/200vac/400Hz |
|
Resistive Inductive Motor Overload Rupture I minimum |
60 (In) 36 60 8 In [1] 10 In [2] In/10 |
|
Auxilary contact rating | (HN) 28Vdc | (BN) 5Vdc |
Resistive Inductive (L/R=5ms) Lamp |
5 2.5 2 |
0.010 - - |
APPLICATION NOTES: 101 102 104 105 007 Balanced-Force Design Hermetically sealed Designed to the performance standards of MIL-PRF-6106 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 28 Vdc and 115 Vac,400 Hz, 1 ?br>and 115/200 Vac 400Hz, 3 ?/b> Weight 400 g Special units available upon request, including models with auxiliary contacts. Optional Ground Fault Protection (GEP) Feature Available. ...
Issued from 5060 series Certification AIR7304 AIR8456B Letter 33746STPA of 02/04/85 Qualification report 2903-LE-92 STPA of 22/01/93 Permanent duty Main contact (2x) 3PST-NO-DM Form X Auxiliary contact (2x) 2NO + 2NC Coil supply Direct current Polarized and protected coil See schematic diagram Meets the requirements of AIR 7304 AIR 8456B AIR 9456 MIL-R-...