Contact rating per pole and load type |
Load current in Amps | |||||
28 Vdc |
115 Vac 400 Hz |
115/200 Vac 400 Hz, 3 ?/b> |
28 Vdc [3] | 28 Vdc [8] |
DELTA 115/200 Vac 60 Hz |
|
Resistive Inductive [2] Motor Load transfer, resistive[7] |
50 30 30 - |
145 145 90 - |
145 145 90 120 |
120 80 80 - |
200 - - - |
60 60 60 - |
Permanent duty Main contact 2PNO - DM Auxiliary contact 1NO + 1NC Coil supply Direct current - Polarized and protected coil See schematic diagram Meets the requirements of AIR 7304 AIR 8456B AIR 9456 MIL 6106J PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 125 A / 28 Vdc Weight - Ref. P/N: 106 450 g ?0% - Ref. P/N: S106 470 g ?0% ...
Letter 30243STPA Permanent duty Main contact 1PNO - DM Auxiliary contact 1NO + 1NC Coil supply Direct current Meets the requirements of AIR 7304 AIR 8456B AIR 9456 MIL 6106J PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 125 A / 28 Vdc Weight - Ref. P/N: 109 ...