Contact rating per pole and load type [1] |
Load current in Amps | ||
@28 Vdc | @115 Vac, 400 Hz, 1?/b> | @115/200 Vac, 400 Hz, 3?/b> | |
Resistive Inductive [2] Motor Lamp Overload Rupture Low level [3] Time current characteristics [4] |
5 3 2 1 20 25 - - |
5 5 3 1 30 40 - - |
5 5 3 - 30 40 - - |
APPLICATION NOTES: 001 007 023 APPLICABLE SOCKET: SO-1066-003 Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current Applicable standard MIL-R-6106 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 5 Amps / 28 Vdc or 115 Vac - 400 Hz Weight 27 grams max Dimensions max. of case in mm 20.6 x 16.3 x 20.6 Hermetically sealed, corrosion res...
APPLICATION NOTE: 001 APPLICABLE SOCKETS: HRCC Non polarized, non latching hermetically sealed relay. Contact arrangement 4 PDT Coil supply Direct current Compatible with MIL-R-39016/39 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 2 Amp / 28Vdc Weight 34 grams max Dimensions of case without mounting brackets 25.65mm x 15.5m x 25.4mm max ?/font> ...