Contact rating per pole and load type [1] |
Load current in Amps | ||
@28 Vdc | @115 Vac, 400 Hz, 1?/b> | @115/200 Vac, 400 Hz, 3?/b> | |
Resistive Inductive [2] Motor Lamp Overload Rupture Low level [3] Time current characteristics [4] |
10 6 4 2 30 40 - - |
10 8 4 2 60 80 - - |
10 8 4 - 60 80 - - |
APPLICATION NOTES: 001 007 APPLICABLE SOCKET: SO-1064-10444/10445 Contact arrangement 2 PDT Designed to the performance standards of MIL-PRF-83536 CECC16303-803 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at Low level, 28 Vdc and 115/200 Vac, 400Hz 3? case grounded Weight 15 grams max Dimensions max. of case in mm 20.6 x 19.3 x 10.4 Special models available upon request Hermetically sealed, corrosion resistant metal can. CONTACT ELECTRIC...
APPLICATION NOTES: 001 007 APPLICABLE SOCKETS: HRCW SO9005 SF250-R4 Non polarized, non latching hermetically sealed relay with bifilar coil. Contact arrangement 2 PDT Coil supply Direct current Qualified to MIL-PRF-39016/22 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 2 Amp / 28Vdc Weight 10 grams max Dimensions of case 20.6mm x 12.5m x 10.4mm max ?/font> ...