价 格: | 面议 | |
型号/规格: | UA-SH-105D/UA-SH-109D/UA-SH-112D/UA-SH-124D | |
品牌/商标: | GOODSHY |
Application
Telecommunication, Domestic Appliances, Office Machine, Audio Equipment, Camera, etc.
Performance (at Initial Value)
Contact Resistance..............100mΩ Max.@100mA, 6VDC
Operate Time........................8 mSec. Max.
Release Time.......................4 mSec. Max.
Dielectric Strength :
Between Coil & Contact…… 500VAC at 50/60 Hz for
one minute.
Between Contacts……………500VAC at 50/60 Hz for
one minute.
Surge Strength……………1,000 V(between Coil
& Contact 1.2x50μSec.)
....Insulation Resistance……… .100 MegaΩ Min. at
500VDC.
Max. On/Off Switching :
Electrical...............................30 Cycles per Minute.
Mechanical...........................300 Cycles per Minute.
Temperature Range..............-25~55°C
Coil Temperature Rise..........40°C Max.
Vibration :
Endurance............................10 to 55 Hz dual
amplitude width 1.5mm.
Error Operation.....................10 to 55 Hz dual
amplitude width 1.5mm.
Shock :
Endurance ..........................500 m/S2.
Error Operation.....................100 m/S2.
Life Expectancy :
Mechanical ..........................107 Operations at No
Load condition.
Electrical .............................105 Operations at Rated
Resistive Load.
Weight..................................About 3.5 g.
Safety Standard & Its File Number
UL.........................................E141060
ApplicationTelecommunication , Office Equipment and IndustrialControl, Application.Performance (at Initial Value) Contact Resistance .............. 100mΩMax.@1A,6VDC Operate Time........................ 5 mSec. Max. Release Time ....................... 3 mSec. Max. Dielectric Strength :Between Coil & Contact ....... 1,000VAC at 50/60 Hzfor one minute.Between Contacts ................ 400VAC at 50/60 Hzfor one minute. Surge Strength ..................... 1,500V (between Coil& Contact 1.2x50μSec.).... Insulation Resistance ........... 100 MegaΩ Min. at500VDC. Max. On/Off Switching :Electrical............................... 30 Cycles per Minute.Mechanical ........................... 300 Cycles per Minute. Temperature Range ..............-30~70°C Humidity Range ....................35~85% RH. Coil Temperature Rise ..........40°C Max. Vibration:Endurance..............
ApplicationTelecommunication, domestic appliances, office machine, audio equipment, Remote Control, etcPerformance (at Initial Value) Contact Resistance.............100mΩMax.@0.1A,6VDC Operate Time.......................GS-D 6 mSec. Max.GS-T 8 mSec. Max Release Time......................4 mSec. Max. Dielectric Strength :Between Coil & Contact.......1,000VAC at 50/60 Hzfor one minute.Between Contacts................500VAC at 50/60 Hzfor one minute. Surge Strength.....................1,500V (between coil& contact 1.2x50μSec.) Insulation Resistance..........100 MegaΩ Min. at500VDC. Max. On/Off Switching :Electrical..............................30 Cycles per Minute.Mechanical 300 Cycles per Minute. Temperature Range..............-30~80°C Humidity Range....................45~85% RH. Coil Temperature Rise..........25°C Max. (D Type)20°C Max. (T Type) Vibration:End...