INPUT | ||
Voltage |
115/230 VAC ± 10%, User selection | |
Frequency |
50/60 Hz ± 5% | |
Fuse |
6.3 Amp 250V Slo-Blo | |
DIELECTRIC WITHSTAND TEST MODE | ||
Output Rating |
5 KV @ 20mA AC | |
6 KV @ 5 mA DC | ||
Output Adjustment |
Range: |
0-5 KV AC, 0-6 KV DC |
Resolution: |
10 volt/step | |
Accuracy: |
± (2% of setting + 5 volts) | |
Voltage Display |
Range: |
0 - 5 KVAC / 0-6KV DC |
Resolution: |
10 volt/step | |
Accuracy: |
± (2% of reading + 10 volts) | |
HI / LO -Limit AC |
Range: |
0.00 - 20.00 mA |
Resolution: |
0.01 mA/step | |
Accuracy: |
± (2% of setting + 0.02 mA) | |
AC Current Display |
Range: |
0.00 - 20.00 mA |
Resolution: |
0.01 mA/step | |
Accuracy: |
± (2% of reading + 0.02 mA) | |
HI / LO - Limit DC |
Range: |
0.00 - 5.00 mA |
Resolution: |
0.01 mA/step | |
Accuracy: |
± (2% of setting + 0.02 mA) | |
DC Current Display |
Range: |
0.00 - 5.00 mA |
Resolution: |
0.01 mA/step | |
Accuracy: |
± (2% of reading + 0.02 mA) | |
Failure Detector |
Audible and Visual | |
Output Ripple |
< 5% (6KVDC/5 mA at Resistive Load) | |
Discharge Time |
< 200 ms | |
Maximum Capacitive Load in DC Mode |
1µF < 1KV , 0.75µF < 2KV, 0.5µF < 3KV, 0.08µF < 4KV, 0.04µF < 5KV, 0.01µF < 6KV | |
AC Wave Form |
Sine wave Distortion : < 2% THD ; Crest Factor= 1.3 – 1.5 | |
Output Frequency |
Range: |
60 or 50 Hz, User Selection |
Output Regulation |
± (1 % of output + 5 volts) from no load to full load | |
Dwell Timer |
Range: |
0, 0.2 - 999.9 sec, (0 = Constant) |
Resolution: |
0.1 sec increments | |
Accuracy: |
± (0.1% + 0.05 sec) | |
Ramp Timer |
Range: |
0.1 - 999.9 sec |
Resolution: |
0.1 sec increments | |
Accuracy |
± (0.1% + 0.05 sec) | |
INSULATION RESISTANCE TEST MODE | ||
Output Voltage |
Range: |
100 - 1000 Volts DC |
Resolution: |
1 volt/step | |
Accuracy: |
± (2% of reading + 5 volts) | |
Voltage Display |
Range: |
0 - 1000 V |
Resolution: |
1 volt/step | |
Accuracy: |
± (2% of reading + 2 counts) | |
Resistance Display |
Range: |
1 - 1000 MΩ (4 Digit, Auto Ranging) |
Resolution: |
0.01/0.1 MΩ | |
Accuracy: |
± (3% of reading + 2 counts) at test voltage > 500V | |
± (7% of reading +2 counts) at test voltage < 500V | ||
HI-Limit |
Range: |
0, 1 - 1000 M Ω (0 = Off) |
LO-Limit |
Range: |
1 - 1000 M Ω |
Delay Timer |
Range: |
0, 0.5 - 999.9 sec (0 = Constant) |
Resolution: |
0.1 sec/step | |
Accuracy: |
± (0.1% + 0.05 sec) |
简单介绍 ·三相可程序输出。·全系列采用脉宽调变(PWM)技术设计(Switching)。·全范围可调输出电压及频率设定范围(0~300V,47~63HZ)。·Extech 6303 6306 6309 6315 6330 6360 6390 63120 高功率、可程序三相交流电源供应器,咨询电话:0512-68551216/68551217/65090040 三相交流电源供应器的详细介绍 ·4组大型LED显示器,可同时显示输出频率、电压、电流、功率/功率因数量测数值。·在阻性负载下波形失真小于1%。·超强输出波峰因子比可达3:1。·内建8个程序记忆组,每组内含5个程序记忆步骤。·可记忆独立的电压、频率及电流、功率、功率因子上下限设定。·可执行自动循环测试,可执行999900次。·可依需求设定以秒 (sec)、分(min)、时(hour) 为测试执行时间单位。·瞬时反应快,在瞬间加重载或除载时波形可于2msec内回复。·特殊的恒流输出设计,可轻易激活马达、压缩机等高激活电流负载。·全范围输出电压的稳压率可达0.5%。·高激活负载能力,可激活额定输出容量3倍之电流而不作限制保护。·高电力密度设计、体积小、重量轻。·内建PLC遥控界面,可执行Test/Reset及P1,P2,P3三组程序记忆的遥控输出。·Extech 6303 6306 6309 6315 6330 6360 6390 63120 高功率...
简单介绍 ·单相可程序输出。·全系列采用脉宽调变(PWM)技术设计(Switching)。·全范围可调输出电压及频率设定范围(0~300V,47~63HZ)。·在阻性负载下波形失真小于1%。·Extech 6503 6505 6510 6520 6530 6540 6560 高功率可程序单相交流电源供应器,咨询电话:0512-68551216/68551217 高功率可程序单相交流电源供应器的详细介绍 ·超强输出波峰因子比可达3:1。·4组大型LED显示器,可同时显示输出频率、电压、电流、功率/功率因数量测数值。·内建8个程序记忆组,每组内含5个程序记忆步骤。·可记忆独立的电压、频率、电流、功率、功率因子上下限设定。·可执行自动循环测试,可执行999900次。·可依需求设定以秒(sec)、分(min)、时(hour)为测试执行时间单位。·瞬时反应快,在瞬间加重载或除载时波形可于2msec内回复。·特殊的恒流输出设计,可轻易激活马达、压缩机等高激活电流负载。·全范围输出电压的稳压率可达0.5%。·高激活负载能力,可激活额定输出容量3倍之电流而不作限制保护。·高电力密度设计、体积小、重量轻。·内建PLC遥控界面,可执行Test/Reset及P1,P2,P3三组程序记忆的遥控输出。·Extech 6503 6505 6510 6520 6530 6540 6560 高功率可程序单相交流...