- 是否安全:安全
- 是否全新:全新
- 封装:纸箱
- 质保服务:一年
- 颜色:图片色
二氧化碳传感器 型号:HS16-MIT2500库号:M398436
MIT2500
CAT IV Insulation testers
■ Insulation testing up to 2.5 kV (New)
and 200 GΩ range in a hand held instrument
■ Guard terminal for high resistance accuracy
(New)
■ Adjustable insulation test voltage from
50 V to 2500 V (New)
■ Stabilised insulation test voltage (New)
■ Rechargeable options for mains and car
charging (New)
■ Single range, faster continuity testing from
0.01 Ω to 1 MΩ (New)
■ Polarisation Index (PI) & Dielectric Absorption
Ratio (DAR)
■ CAT IV 600 V applications
DESCRIPTION
The MIT2500 insulation and continuity tester has been designed for
Electrical and Industrial test applications, where operation voltages
exceed 1000 V and higher insulation test voltages are needed.
The MIT2500 offers both fixed range voltages of 50 V, 100V,
250 V, 500 V, 1000 V and 2500 V, as well as a variable range that
allows any voltage between 50 V and 2500 V to be “dial in”.
This is supported by the new test voltage feedback control, which
maintains the output test voltage to within 2% of the selected
range, even when under test.
The MIT2500 uses the redesigned case, back-stand, and 6 cell
battery compartment, as well as incorporating a Guard terminal
to reduce surface tracking currents that reduce accuracy at higher
voltages.
All instruments are over-moulded for increased protection and
achieve an IP54 weatherproof rating
INSULATION RESISTANCE TESTING
The feedback control insulation test voltage is now accurate
to +2% -0% compared to the original +20%, providing a more
accurate test voltage without the risk of over-voltage damage to
circuits.
A variable range allows the exact test voltage to be selected from
50 V to 999 V in 1 V steps, (1KV to 2.5KV in 10 V steps) providing
1100 test voltage options.
FEATURES INCLUDE:
■ Test voltages (New)
- 50 V, 100 V, 250 V, 500 V, 1000 V, and 2500 V
■ Guard terminal
- Improved performance on higher insulation test ranges
■ 2.5 kV Silicone test leads (New)
- Purpose designed high 2.5 kV silicone test leads are included as
well as standard 1000 V CAT III / 600 V CAT IV general purpose
test leads.
■ Variable test voltage (New)
- Adjustable test voltage from 50 V to 999 V in 1 V steps,
1000 V to 2500 V in 10 V steps
■ 2% Test voltage accuracy
- The output test voltage is maintained within the tolerance of
-0% +2% +2 V
■ Stabilised test voltage
- The voltage is feedback control to ensure it remains within
specification throughout the full test range
■ Test voltage display (New)
- The actual test voltage is displayed on the smaller digital
readout, with the measurement on the larger digital display.
■ Measurement range displayed
– The range voltage is displayed during selection.
■ Measurement voltage display (New)
- The measurement voltage is displayed during the test.
二氧化碳传感器二氧化碳传感器二氧化碳传感器二氧化碳传感器
■ Analogue arc