Product DetailsProduct Introduction

Quick details.

Place of Origin: Zhejiang, China (Mainland)
Brand Name: Mseed
Model Number:DDSY28-1
Phase: Single  Phase
Input Voltage: 220/230V
Dimensions: 164*110*68(mm) 
Operating Temperature: -10℃~+50℃
Output Frequency: 50 or 60Hz  energy meter with rs485


Features

Main features:  Application of computer management, power utilization after purchasing power; limitation of maximal service power within the rated current range (prescribed by power supply department); one card only for one watt-hour meter, no electricity interruption even with the loss of the card and ensuring the power continuation after the re-registration; bilateral tranission of data and automatic power- cutting off to warn users to purchase power ; automatic switch-off operation when the electric quantity hits zero ; certain software design of anti-electricity-theft and so on . 

single phase prepaid energy meter
Installed in the watt-hour meter boxes indoors or outdoors, the DDSY28-1 serial of electronic watt-hour meters apply to active power meter of frequency of 50HZ or 60HZ. Its ambient temperature ranges from -10℃ to 50℃ and its relative humidity is no more than 85%. It should stay away from the influence of corrosive gas, dust, salt mist and condensation.   energy meter case


Starting Current 
Under the conditions of the rated voltage, rated frequency and power, meter cl I starts at 0.004Ib, meter cl II starts at 0.005 Ib.  single phase energy meter


Watt-hour meter running without load
When the line circuit of the watt-hour meter does not have current, and the line circuit has 115% rated power, the output pulse will not be more than one.   single phase prepaid energy meter

Power dissipation 
≦2W、10VA

Parameters

TeCl indexBasic current 
Display Mode
Interface Mode
DDSY3666Cl 1 or Cl 25(20)ALED ,  LCDPulse
Load Current Power FactorIntrinsic Error(%)
Cl 1Cl 2
0.05Ib1.0±1.5±2.5
0.1Ib-Imax1.0±1.0±2.0
0.1Ib0.5L 0.8C±1.5±2.5
0.2Ib-Imax0.5L 0.8C±1.0±2.0

Applications

1. The watt-hour meter can be installed for use after being certificated and the seal with lead print. If there’s no seal with lead print or too long storage time , the watt-hour meter can’t be used until the department concerned does the rechecking and sealing.

2.The watt-hour meter should be installed in a dry and ventilated place. The soleplate for installing the meter should be fixed in the wall that is stable, fireproof and hard to vibrate and the watt-hour meter should be about 1.8m from the ground. 

3.Do the connection according to the wiring diagram, screw down the wiring bolt and fasten the plug board in terminal box.

4.The number of actual electrical energy must come from the displayed number via mutual inductor cut-in meter multiplying the voltage ratio.

5. “One watt-hour meter, one card”: All users’ cards can’t exchange with each other. Another card should be purchased at the power supply department (power-sale office) after the loss. 

6.Preparations for purchasing power: Users should insert IC card into the holder one time so as to send the watt-hour meter data back to computer database. 

7. Power-purchasing ways: During the process of power-sale, insert IC card into the reader-writer of IC cards while reading into IC card the enciphered information by computer: the user number, power quantity pre-purchased , alarm power, way of restricting capacity and frequency of restricting capacity and so on. 

8.Using power card: Insert power card into the holder for more than 5 seconds. If the card is valid, the watt-hour meter will automatically show the data. The display of LCD will be in the order of : the power quantity purchased, the total power quantity purchased, alarming quantity of electricity , limit of quantity of electricity on credit and frequency of restricting capacity . Ensure the safekeeping of the card after drawing it out. 

9.Working display: During the working process of watt-hour meter, remnant power, total electricity consumption will be shown alternately. 

10.Alarm when over maximum power: During the working process of watt-hour meter, the fast flashing light of “alarm light” warns the user the over maximum power. If the watt-hour meter is set to be switched off due to over the maximum power. The watt-hour meter will be switched off for three minutes if the users use power under the condition of over the maximum power for 60 seconds. at the same time countdown of 180 seconds is shown to reinstate the electricity supply. If the users insert the card into the watt-hour meter, then the power can be restored at once. 

11.Hoarding limit: If power quantity purchased+ remnant power ﹥Hoarding limit(10000kwh), power quantity purchased won’t be read in ,and monitor will show “remnant power ” and the power in the card will still be valid. 

single phase energy meter   prepaid energy meter       

12.Alert reminder: When the remnant power in the card is less than “the quantity of electricity to the limit of light alarms ”, “alarm light” will flash at a 1-second interval to remind users to purchase power. 

13.Power failure warning: When remnant power is less than “the quantity of electricity to the limit of power cuts ” , power is cut to alarm users and “Power-cut ”prompt is showed. At this moment users insert IC card into the holder, the power will be recovered immediately. If IC card to its watt-hour meter can’t be found after power-cut, users can borrow neighbors’ IC card to insert into the holder to recover power supply. 

14.Power supply reminder: when remnant power in the watt-hour meter is less than “the quantity of electricity to the limit of alarm” , “alarming light” will be on all the time as a warning. 

15.Malfunction report: When remnant power is displayed zero or a negative number, “power-cut ” prompt will be shown. If watt-hour meter is sill working, users should purchase power at once and report this condition to power supply department. 

DimensionPacking Details

Being packed according to the international standard is to guarantee safe delivery during the transportation. 

Why Choose Us

?Professional manufacturer with internationally standard production lines and a devoted technical team. 

?Strict test procedure with advanced test equipment 

?Responsive and responsible service team. 

?Door to door service when needed. 

?Helpful and enthusiastic in developing the buyers’ business. 


?Treat your career as our career. 

Certifications:

Welcome to contact us:

For sales or information inquiry, please contact us in the following ways:
Mob:+8613588948320
Tel: +86-
Ske: angelwu7777(+0)
Trade messenger:Angel Wu


联系方式

温州麦子电器有限公司

联系人:
Justin Bao女士
手机:
18017341393
传真:
0577-55770369
所在地:
上海市
类型:
工厂
地址:
No.2218 xinsongjiang Rd. Songjiang, Shanghai, China

服务热线

021-57871618

QQ:3530118834 
提示:您在维库仪器仪表网上采购商品属于商业贸易行为。以上所展示的信息由卖家自行提供,内容的真实性、准确性和合法性由发布卖家负责,请意识到互联网交易中的风险是客观存在的。 请广大采购商认准带有维库仪器仪表网认证的(金牌会员、VIP会员、至尊VIP会员、百维通)供应商进行采购!
个人中心
商家客服

商家客服
专业的人工客服服务

QQ:3530118834 

商家电话

人工服务电话
021-57871618

顶部
立即询价
手机访问

扫一扫
进入手机店铺