Model F1210 Optionen Nominal load Fnom 0,5, 1, 2, 5, 10, 20, 50 kN Accuray cl 0,5% of F.S. Limit load 150% Fnom Breaking load >300% Fnom Combined error ≤± 0,3% of F.S. Max. dynamic load ± 70% of Fnom acc. to DIN 50 100 Creep, 30 min. at Fnom <± 0,1% of F. S. Nominal defleion <0,2 mm Service temperature range -30 up to +80°C Storage temperature range -50 up to +95°C Reference temperature 23°C Temperature effe -span -zero ±0,2% of F.S. / 10K ±0,2% of F.S. / 10K Insulation resistance > 2 GW Analogue output -output signal -Bridge resistance -Option
-Tolerance of span -Excitation voltage -Option -Elerical conneon 1 mV/V 350 W Cable integrated amplifier 0 (4) … 20 mA, 0 … 10 V DC ≤± 0,5% of F.S. 2 … 12 V (15 V max.) 16 … 32 V DC for cable integrated amplifier cable 3 m / 4-wire, shielded
Fastening screw thread Calibration control 100% signal Cable output Axial £ 20 kN Sensorinterface LCV 0... ±10 V bzw.- or 0(4)...20 mA LCVU or LCVI Material of measuring device stainless steel Weight (kN) -0,5 - 2 -5 - 20 -50 0,07 kg 0,08 kg 0,32 kg