- 产品品牌:
- TECHNIX
- 产品型号:
- 2500-5000J/s CCR系列
法国TECHNIX高压充电电源,主要作为高压电容器以及MARX发生器等设备的充电电源。
- Voltage & Current Outputs continuously adjustable from 0 to full scale
- High precision regulation
- Total protection against arcs, overloads and short circuits
- Over Temparature protection
- High reliability & efficiency
- Double Resonance Technology (ZVC)
- V & C Setting and Monitoring from front panel or REMOTE
- Automatic crossover
- Over Current Limitation and Protection functions
- Remote, Inhibit & Interlock functions
- Polarity display and 3½ digit displays
- Safety switch key
- Master-slaves architecture or Control Unit to 6 modules
* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 45 000 V generator based on 6 000 W model. In this case, you will get an Output Voltage adjustable from 0 to 45 000 V and an Output Current from 0 to 133.3 mA.
- Output Voltage and Output Current: Both Voltage Output and Current Output are continuously adjustable from 0 to 100 % (full scale).
- Reproducibilty (pulse to pulse voltage variation): Load Regulation: ± 0.25 % (Frequency < 10 Hz)
- Current regulation: Load Regulation: ± 0.05 % (for 0 - 100 % load change)
- Voltage Holding: 0.25 % p-p (better on request)
- Stored Energy: 0.2J/kJ
- Protections: Against short circuit & HV arc to ground
- Temperature Coefficient: 100 ppm/°C
- Efficiency: > 90 % full load
- Stability (after one hour warm-up): 0.01 % / hour, 0.03 % / 8 hours of operating with constant load and ambient temperature.
- Temperature Coefficient: 100 ppm/°C
- Operating Temperature: from 0 to 40°C
- Air Cooling
- Mains Voltage: 400 VAC ± 10 % 47 − 63 Hz 3 Phases + Earth
- Inrush current: limited to full power operating current
- Power factor: > 0.98
- Calibration: with probes periodically approved by Authorized
- CE Marking
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V
Line Regulation: ± 0.1 % ( for Main Voltage ± 10 %)
Line Regulation: ± 0.05 % (for Main Voltage ± 10 %)
Shutdown on Overtemperature, & open interlock