| MODEL | | | 7110 | 7112 | 7120 | 7122 | |
| | AC WITHSTAND VOLTAGE | | | | | | | | |
| | Output Rating | | 5KVAC/12mA | |
| | | | | Range | Resolution | Accuracy | |
| | Output Voltage,KVAC | 0-5.00 | 0.01 | ±( 2% of setting +5V ) | |
| | Output Frequency | | 50Hz/60Hz±100ppm,User Selection | |
| | Output Waveform | | Sine Wave,THD<2%( Resistion Load ),Crest Factor = 1.3-1.5 | |
| | Output Regulation | | ±( 1% of output +5V ),Form no load full load | |
| | SETTINGS | | | | | | | | | | |
| | Hi-Limit AC Current,mA | 0.10-12.00 | 0.01 | ±( 2% of setting +2counts ) | |
| | Lo-Limit AC Current,mA | 0.00-12.00 | 0.01 | ±( 2% of setting +2counts ) | |
| | Ramp Time,second | | 0.1-999.9 | 0.1 | ±( 0.1% + 0.05sec ) | |
| | Dwell Time,second | 0,0.2-999.9 | 0.1 | |
| | ( 0=continuous ) | |
| | Arc Detection | | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) | |
| | DC WITHSTAND VOLTAGE(7120,7122 ONLY) | | | | | | | |
| | Output Rating | | 6KVDC/5mA | |
| | Output Voltage,KVDC | 0-6.00 | 0.01 | ±( 2% of setting +5V ) | |
| | Output Ripple | | < 5% ( 6KV/5mA at Resistive Load ) | |
| | SETTINGS | | | | | | | | | | |
| | Hi-Limit DC Current,mA | 0.02-5.00 | 0.01 | ±( 2% of setting +2counts ) | |
| | Lo-Limit DC Current,mA | 0.00-5.00 | 0.01 | ±( 2% of setting +2counts ) | |
| | Ramp Time,second | | 0.1-999.9 | 0.1 | ±( 0.1% + 0.05sec ) | |
| | Dwell Time,second | 0,0.2-999.9 | 0.1 | |
| | ( 0=continuous ) | |
| | Arc Detection | | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) | |
| | Discharge Time | | ≦200msec | |
| 7110/7112/7120/7122实用数位合成型耐压/绝缘测试仪 |
| | MODEL | | | 7110 | 7112 | 7120 | 7122 | |
| | INSULATION RESISTANCE ( 7112,7122 ONLY ) | | | | | | |
| | Output Rating | | 1KVDC/1000MW | |
| | Output Voltage,KVDC | 0.10-1.00 | 0.01 | ±( 2% of setting +3V ) | |
| | SETTINGS | | | | | | | | | | |
| | Hi-Limit Resistance,MW | 0,1-1000(0=OFF ) | 1 | ±( 3% of setting +2counts ) at ≧ 500VDC | |
| | Lo-Limit Resistance,MW | 1-1000 | 1 | ±( 7% of setting +2counts ) at <500VDC | |
| | Delay Time,second | 0,0.5-999.9 | 0.1 | ± ( 0.1% + 0.05sec ) | |
| | ( 0=continuous ) | |
| | GENERAL | | | | | | | | | | |
| | Input Voltage AC | | 115/230VAC±15%,50/60Hz±5%,Fuse 3.15A Fast | |
| | PLC Remote Control | Input: Test,Reset | |
| | Output: Pass,Fail,Processing | |
| | Memory | 5 Sets store/Recall of each Memory,4Test Mode Selectable ( W,I,W-I,I-W Only 7112,7122) | |
| | Display | 16×2 LCD with back light | |
| | Key Lock | To prevent unauthorized alteration of test parameters | |
| | Calibration | Build-in software and external calibrated meters | |
| | Environment | 0-40℃,20-80%RH | |
| | Dimension/Net Weight | 280mm(W)×89mm(H)×370mm(D)/9Kg | |
| | ※Ordering Information※--------------------------------------------------------------------------------- | |
| | 7110 AC Withstand Voltage Tester | |
| | 7112 AC Withstand Voltage / Insulation Resistance Tester | |
| | 7120 AC/DC Withstand Voltage Tester | |
| | 7122 AC/DC Withstand Voltage / Insulation Resistance Tester |