- 企业类型:贸易商
| Features | |||
| Brief description: | Small connection module for one sensor, 4 cable glands, base for CMC600 | ||
| Supported products: | CLV42x, CLV43x, CLV44x, CLV45x, CLV48x, CLV49x, CLV62x, CLV63x, CLV64x, CLV65x, CLX49x, ICR84x-2, ICR85x-2, LECTOR?62x, RFH62x | ||
| Supports cloning module (CMC): | yes | ||
| Supports display module (CMD): | no | ||
| Supports power supply module (CMP): | no | ||
| Supports fieldbus gateway (CMF): | no | ||
| Interfaces | |||
| Serial (RS-232, RS-422/485): | |||
| Remark (Serial (RS-232, RS-422/485)): | depending on sensor connected | ||
| CAN bus: | |||
| Remark (CAN bus): | depending on sensor connected | ||
| Ethernet: | - | ||
| PROFIBUS: | - | ||
| PROFINET: | - | ||
| DeviceNet: | - | ||
| Switching inputs: | depending on sensor connected | ||
| Switching outputs: | depending on sensor connected | ||
| Optical indicators: | 9 LED | ||
| Mechanics/electronics | |||
| Power consumption: | 16 W | ||
| Housing: | Polycarbonat | ||
| Enclosure rating | IP 65 (DIN 40 050)1) | ||
| Protection class: | III (VDE 0106) | ||
| Weight: | 250 g | ||
| Dimensions: | 124.2 mm x 113.1 mm x 53.9 mm | ||
| Housing color: | Blue (RAL 5012) | ||
| Scanner connection: | 15-pin D-Sub HD socket | ||
| Service plug: | 9-pin D-Sub HD socket (internal) | ||
| 1)When using a SICK scanner standard connecting cable |
| Ambient data | |||
| Ambient operating temperature: | 0 °C ... 40 °C | ||
| Storage temperature: | -20 °C ... 70 °C | ||
| Permissible relative humidity: | 90 %, non-condensing | ||