您好,欢迎来到维库仪器仪表网 网站登录 | 免费注册 | 忘记密码
商铺首页 公司介绍 公司动态 产品中心 技术资料 在线留言 联系我们
CIRS 055 模体
CIRS 055 模体
  • CIRS 055 模体
  • CIRS 055 模体
  • CIRS 055 模体
  • CIRS 055 模体
  • CIRS 055 模体
扫一扫

扫一扫
进入手机店铺

CIRS 055 模体

产品价格:
电议
产品型号:
055
产品品牌:
CIRS
供应商等级:
企业未认证
经营模式:
代理商
企业名称:
北京华贺技术有限公司
所属地区:
北京市
发布时间:
2020/2/27 17:06:17

产品搜索

手机访问

扫一扫
进入手机店铺

  • 企业类型:贸易商
  • 新旧程度:全新
  • 原产地:美国

美国CIRS 三维超声校准模块-CIRS模体系列055

CIRS 055 模体

  For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements. Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability. Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods. The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.The basic standard for ultrasound quality assurance. The series of ultrasound phantoms, unlike human subjects or random scannable materials, offers a reliable medium which contains specific, known test objects for repeatable qualitative assessment of ultrasound scanner performance over time. This phantom is constructed from the patented solid elastic material Zerdine?. Zerdine?, unlike other phantom materials on the market, is not affected by changes in temperature. It can be subjected to boiling or freezing conditions without sustaining significant damage. Zerdine? is also more elastic than other materials and allows more pressure to be applied to the scanning surface without subsequent damage to the material. At normal or room temperatures, the Zerdine? material found in the Model 054 will accurately simulate the ultrasound characteristics found in human liver tissue. Designed to allow for axial resolution, lateral response width, uniformity, dead zone measurements, depth of visualization, high and low contrast mass imaging, and distance calibration. ?Fully complies with all requirements and recommendation of the AIUM and ACR.

CIRS 055 模体

提示:您在维库仪器仪表网上采购商品属于商业贸易行为。以上所展示的信息由卖家自行提供,内容的真实性、准确性和合法性由发布卖家负责,请意识到互联网交易中的风险是客观存在的。 请广大采购商认准带有维库仪器仪表网认证的(金牌会员、VIP会员、至尊VIP会员、百维通)供应商进行采购!
个人中心
顶部
立即询价
手机访问

扫一扫
进入手机店铺